Commercial (UL/CSA)

UL 5210

Additional Details

APPLIANCE WIRING MATERIAL
Style 5210 Multi-conductor Cable with Extruded Non-Integral Jacket.
Rating 80 deg C, 30 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
Conductor Fiber Optic. 4 mils minimum diameter, 6 mils maximum diameter.
Buffer Optional – SR or PE coating.
Covering Inner. Optional – Nylon or PE.
Insulated Conductor Labeled or complying with manufacturer’s AWM procedure.
Assembly One or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite optic core – One or more glass fiber core covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional. Manufacturer shall intain a complete description of each assembly.
Shield Optional.
Covering Outer. Optional – PVC, 5 mils minimum thickness at any point.
Jacket Extruded PVC
Diameter of core assembly under jacket Minimum average thickness Minimum thickness at any point
0.700 inch or less 30 mils 24 mils
0.701-1.000 inch 60 mils 48 mils
1.001-1.500 inches 80 mils 64 mils
1.501-2.500 inches 110 mils 88 mils
2.501 inches and larger 140 mils 112 mils
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring or External Interconnection of Class 2 Circuits of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2014


If you don’t find what you’re looking for please contact us. The cable designs in this listing represent our standard product line. If you require special modifications or unique designs, SCC can create special cables for the most demanding applications. For custom applications please contact us.